- CleanWhite® Pure — Patented 405nm LED
Better light. CRI 90+ color rendering and the best photobiological safety rating possible.
CleanWhite Pure is a patented single-chip LED that produces a fundamentally cleaner spectrum than conventional lighting. No 450nm blue spike. No circadian disruption. Just high-quality white light, with CRI 90+ color rendering and a photobiological safety rating no other white light LED has achieved.
CRI 90+
Higher color rendering than conventional LEDs, from a cleaner, broader spectrum
ZERO
Blue light spikes. No 450nm pump peak, no 470nm circadian spike
RG 0
405nm
Patented wavelength that produces antimicrobial wavelengths of visible light while it illuminates
The Spectrum
Conventional LEDs have a blue light problem. CleanWhite Pure doesn't.
Spectral Power Distribution
Visible spectrum, 380nm to 700nm
CleanWhite Pure has a narrow peak at 405 nanometers and a broad secondary spectrum around 600 nanometers. The conventional LED has a flat-topped primary peak between the 450 and 470 nanometer reference guides.

CleanWhite Pure vs Conventional LED
405NM
CleanWhite Pure, 405nm chip
Single-chip 405nm emission converts through phosphor to produce CRI 90+ white light with no blue peaks. The cleaner spectral base enables both the higher CRI and the IEC 62471 RG 0 safety rating; they come from the same design decision.
450NM
Conventional LED, 450nm blue spike
The 450nm pump spike was not a design choice. It is a product of trying to make LEDs as efficient as possible in a rapidly scaling market. This spike cannot be filtered out by phosphor, lowering CCT, or turning the lights down. It is present in every conventional white LED at full intensity, every hour the fixture operates.
470-490NM
Circadian LEDs
Some products add 470-490nm LEDs, close to the melanopsin peak (~480nm), to boost daytime alertness. The catch is timing. The same light that helps in the morning suppresses melatonin in the evening, and unless the fixture is tuned by time of day, it sends that signal around the clock. CleanWhite Pure keeps its output away from that peak, so the space isn’t sending a daytime signal at night.

Color Rendering Index (CRI) 90+: because better light starts with a better spectrum.
Where CRI 90+ matters by vertical
01
Healthcare & Surgery
Accurate tissue color assessment, wound evaluation, and specimen identification. High CRI reduces misread risk in clinical tasks.
02
Dental
Shade matching and enamel assessment require accurate color rendering. CRI 90+ is the minimum standard for serious clinical dentistry.
03
Grocery & Retail
Produce, meat, and packaged goods look more appealing under high-CRI light. Better color rendering drives purchase confidence.
04
Education & Office
Natural-quality light reduces visual fatigue over long occupancy periods. Students and staff sustain focus longer under a cleaner spectrum.
05
Design
Conveying the right colors to clients is imperative to managing expectations. Using a CRI that works closer to natural light means the most accurate results.
OCULAR HEALTH AND HUMAN WELLBEING
The light people spend their days under should not be working against them.
Most people spend eight to twelve hours a day under artificial light.
Conventional LEDs are designed for efficiency, not for the biology of the people underneath them. The 450nm blue spike that enables standard white LED output is the same wavelength range most implicated in retinal phototoxicity, digital eye strain, melatonin suppression, and circadian disruption. CleanWhite Pure removes it entirely.

Blue light hazard
The IEC 62471 blue light hazard function, B(λ), peaks between 435 and 450nm, the exact range where conventional LEDs concentrate their output. Removing the 450nm pump eliminates that peak, which means less cumulative ocular exposure over the fixture’s life in clinics, schools, and gyms. That’s why CleanWhite Pure earns an Exempt (RG 0) rating on IEC 62471, while conventional LEDs can score as high as RG 2.
Visual comfort
Circadian neutrality
Long-term exposure
- No 450nm spike
- CRI 90+
- Reduced glare
- Circadian-neutral
- Patented (US, EU, Japan)
- Safe for unlimited daily exposure
SPECTRAL POSITION, WHERE 405NM SITS
The only visible wavelength with antimicrobial action that doesn't touch the circadian system.
The visible spectrum is not uniform in its effects on human biology. Different wavelength bands interact differently with the eye, the circadian system, and microbial chemistry. CleanWhite Pure’s 405nm anchor sits in a precise position: above UV, below the blue-light hazard window, and below the melanopsin curve—while remaining in the only visible wavelength range with proven antimicrobial activity.
Berson DM, Dunn FA, Takao M. "Phototransduction by retinal ganglion cells
that set the circadian clock." Science.
2002. Melanopsin peak ~480nm; sensitivity declines sharply below 450nm.
And one more thing
The same chip that lights better also produces antimicrobial wavelengths of visible light.
The 405nm wavelength that gives CleanWhite Pure its clean spectrum and superior color rendering is also the only visible wavelength with peer-reviewed, demonstrated antimicrobial efficacy. It is not a separate function. The same chip delivers both benefits every hour the light is on.
405nm photons are absorbed by naturally occurring porphyrins within bacteria, fungi, and enveloped viruses. This creates reactive oxygen species, including superoxide, singlet oxygen, and hydroxyl radicals, which cause irreversible oxidative damage to the pathogen’s cell membrane, proteins, and DNA. The pathogen is destroyed from within. No added agent. No UV. No downtime.
Continuous, no cycles, no downtime.
As long as the light is on, the space is being treated. No scheduling, no evacuation, no staff involvement required.
Safe for fully occupied spaces.
IEC 62471 RG 0 means CleanWhite Pure's antimicrobial wavelengths can be produced in ORs, patient rooms, classrooms, and gyms, with people present, without restriction.
Not a replacement for UV-C.
CleanWhite Pure produces antimicrobial wavelengths of visible light continuously, but it is not a substitute for terminal sterilization. For high-risk terminal events, UV-C or chemical protocols remain appropriate.
No resistance development.
Photoinactivation targets multiple cellular systems simultaneously. Unlike antibiotics or chemical disinfectants, pathogens cannot develop resistance to oxidative ROS damage.
Questions about the spectrum.
Conventional LEDs produce light by exciting a phosphor coating by utilizing a high-energy blue wavelength, centered around 450nm. The spike is not a design choice, it was historically, the most energy efficiency way to make LEDs work. It cannot be filtered or removed without sacrificing output. A spike always remains even if CCT or power is adjusting.
The 450nm range sits at the peak of the IEC 62471 blue light hazard function, meaning it carries the highest weighted risk for ocular damage and stress through exposure. People are aware that the light in their phones might be bad, but they discount the lights above their heads. Over 8 to 12 hours of indoor time a day, most people are absorbing far more high-energy blue light that any single source suggests, even if they limit their screen time.
CleanWhite Pure eliminates the 450nm spike entirely by anchoring at 405nm instead. The result is a cleaner spectral base, a higher CRI, and the best photobiological safety rating.
Yes, and it is worth understanding why. Screens are a significant and growing source of blue light exposure in the 450nm range. Unlike overhead lighting, screens are held close to the face for hours at a time.
The cumulative daily dose of high-energy blue light now comes from multiple sources simultaneously: the fixture overhead, the monitor on the desk, and the phone in hand. Reducing blue light exposure in the built environment matters more as screen use increases, not less.
CleanWhite® Pure addresses the architectural source, which is the lighting itself, so the space does not compound the exposure already produced by screens.
Yes. CleanWhite® Pure is certified to IEC 62471 Risk Group 0, the exempt category for photobiological hazard. This means there are no exposure-time restrictions for the eyes or skin. It is designed to operate continuously in spaces where people live, work, and heal. No room clearance, downtime, or waiting period is required.
The 450nm spike is not only a health concern; it is also an optical concern. Because conventional LEDs concentrate energy within a narrow blue band, the remainder of the spectrum becomes compressed. A CRI of 80 reflects that imbalance. CleanWhite® Pure’s cleaner spectral foundation distributes energy more evenly across the visible range, allowing it to achieve CRI 90+ without additional tuning or hardware.
Eight to twelve hours under conventional lighting represents a meaningful dose of high-energy blue light before a single screen enters the picture. The 450nm spike present in every standard LED falls within the same wavelength range associated with retinal phototoxicity, eye strain, and circadian disruption in occupational health literature.
CleanWhite® Pure eliminates that spike at the source, earning the best photobiological safety rating possible under IEC 62471. The result is less cumulative exposure every day, in every room where it operates.
The peer-reviewed studies supporting CleanWhite® technology, along with certifications and testing summaries, are available on request. Reach out and we will share the research most relevant to your facility type, or view our scientific validation data.
- CleanWhite Pure